Rheem Furnaces

Error Code 68

Troubleshooting guide for the Rheem Furnaces system fault 68.

Disclaimer: This information is for general reference. Error codes can vary by model and production year. Always refer to your machine's specific manual and the information printed on the unit itself.

System Diagnosis

No blower communication.

Potential Causes & Solutions

  • Disconnected or poor wiring connection between furnace control and blower motor, no line voltage to motor, faulty/corrupted model data, failed ECM motor, or failed control/motor communication circuit.

Verify Before Replacing Parts

  1. Confirm the exact Rheem model family and furnaces context before acting on a generic code description.
  2. Confirm board LEDs, wiring polarity, and model compatibility before replacing control boards.
  3. Check for intermittent communication faults caused by connectors, moisture, or damaged harnesses.
  4. After the correction, run the system long enough to confirm the code does not return under normal load.

Field Signals to Confirm

What usually confirms it

Loss of comm LEDs, incorrect polarity, or a fault that appears only when indoor and outdoor boards talk.

What can fool you

Board swaps without harness checks can hide the real fault if the wiring path is damaged.

When to Escalate the Call

  • Communication faults persist after polarity, harness, and compatibility checks.
  • A board replacement seems likely but the full system path has not been confirmed.